Insulation Quote Form
Get a formal quote on reflective or fiberglass insulation for your steel building.
Available quotes: 30′ x 30′ x 12′ to 100′ x 500′ x 30′. $1,000 guarantee savings!
Get a formal quote on reflective or fiberglass insulation for your steel building.
Factory Steel Overstock est. March 2011, has A+ Grade, has a 5 Star rating and ALL positive reviews posted at the BBB. Click BBB logo to read reviews.
Factory Steel Overstock
1250 Cherokee St Unit #1815
Denver, CO 80204
(888) 512-1116
If you believe you have found a quote lower than our listed or quoted price, email it to factorysteeloverstock@gmail.com and take advantage of our guaranteed savings program. Also, we are always wanting your feedback.
(Mainframes)
SOLID I-BEAM CONSTRUCTION
Material used is minimum 50,000 p.s.i. yield strength. (Some manufacturers use 35,000 p.s.i. yield strength material, which is not as strong). Frames are single bead, continuous submerged arc welded by automatic welding machines to help insure quality. A factory-applied rust inhibiting primer is used to help protect the mainframes and secondary material during the erection process.
ENDWALL FRAMES AND COLUMNS
are either cold formed, hot-rolled or built-up “I” sections depending on design requirements.
GIRTS (in sidewall) and PURLINS (in roof) are minimum 8” to meet design requirements. Cold rolled Z-section, 12 to 16 ga ASTM A-653, 55,000 p.s.i. yield material is used to provide maximum strength.
Bypass girt system overlaps at sidewall columns forming a continuous “span” for extra strength. All girt clips are factory welded for easier erection.
PURLINS are top-mounted on the rafter with a varied lap of 1’6” to 5’ for strength and cost savings in erection labor. Maximum purlin spacing is 5’ on center.
EAVE STRUT is a cold-formed C-section that is rolled for the appropriate roof pitch to help insure weather tightness at the eave.
RAKE ANGLE is a 2×4 angle supplied for the attachment of the sheeting at the rake of the building for ease of installation.
BASE ANGLE is a 2×4 angle supplied for the attachment of the base of the sheeting to the concrete. The base angle is to be attached to the concrete with ram-sets or equivalent anchors.
BRACING All diagonal galvanized cable bracing is supplied for roof and walls to remove longitudinal load from the structure. Galvanized cable is used rather than solid rod to prevent the bracing from “sagging” under its own weight and it is easier to install. All cables are pre-stressed and pre made for easier erection.
Angle Flange Bracing is provided for the connection of the rigid frame to the purlins and girts. This insures the allowable compressions are adequate for any combination of loading.
FRAMED OPENINGS have cold-formed C-section jambs and headers to help insure easy installation of overhead doors, etc.
24 or 26 gage 80,000 P.S.I. yield strength material standard. Some manufacturers use a lower yield strength material, which is less resistant to damage from hail or other impacts. 40 year warranty on premium color finish on walls and trim. Roof finish is galvalume or premium colored finish
ALL COIL STEEL has a minimum of G-90 class Galvalume substrate (1.25oz hot dipped) to help prevent deterioration of the steel sheeting.
DEEPER HIGH-RIB SHEETING (PBR) with more frequent corrugations provides extra strength.
STRUCTURAL BOLTS meet requirements ASTM Standards.
A-325 for primary frame connections
A-307 for secondary framing
SELF-DRILLING AND SELF-TAPPING FASTENERS are pre-assembled with neoprene washers and metal caps to help insure weather tightness.
CLOSED CELL NEOPRENE STRIPS are used to help seal building. Located at eave, gable, and optional at the base of building to help provide weather tightness. Pre-formed shapes to match panel configuration providing a tighter seal.
1-1/2” SHEETING NOTCH at base of concrete where panel site is designed into every building. Sheeting notch provides an air infiltration stop on blanket insulated building.
SEALANT for roof sidelaps, endlaps and flashing at gable is provided to help insure weather tightness. Nominal 3/8” x 1/8” thick pressure sensitive tape sealant for ease of installation.
LONG OVERLAP to help prevent water from siphoning into building.
All buildings are fully trimmed at rake (gable), corners, and eaves with standard trim material for a more finished look. This not only improves look of building, it is an additional deterrent to moisture, insects, and dirt from getting into the building.
ANCHOR BOLT setting plan, building reactions for foundation design, Erection Manual, and Engineer
Letter of Certification is provided shortly after receipt of deposit for building.
ERECTION DRAWINGS provide step by step instructions for case of assembly by dealer or customer.
ENGINEER CERTIFIED APPROVAL DRAWINGS including wall and roof framing diagrams, cross sections, sheeting, and flashing details are provided. These drawings clearly show the proper erection and assembly of all building components.
ALL PARTS ARE NUMBERED A part number is placed on each component (not including sheeting,screws, etc.). These part numbers coincide with a detailed listing contained in the bill of materials that come with your building. They same numbers are also used on the drawings for clarity and to help with assembly on the jobsite.
FOUNDATION PLANS – WE HAVE: Certified Foundation Plans (additional cost) for the following states: WA, OR, CA, ID, NV, AZ, WY, UT, CO and NE.
Features | Option 1 | Option 2 | Option 3 |
---|---|---|---|
Cost for Quote | Free Online Prices | Free Online Prices | Free Online Estimator - OR - $100 Refundable Custom Quote |
Customer Service | From Order to Delivery and Beyond! | From Order to Delivery and Beyond! | From Order to Delivery and Beyond! |
Packages | 4 Base Models - Assorted Accessories already Included in pricing! | 7 Base Models - You add desired accessories. | Personalized: You make the choices from Non-Complexity Building Design or CALL for High-Complexity Building Design Quote |
Dimensions Available | Min: 30' x 40' x 10' Max: 50' x 100' x16' | Min: 30' x 40' x 12' Max: 50' x 100' x 16' | Min: 24' x 30' x 10' Max: 100' x 500' x 30' |
Rollup Doors | 1 or 2 Insulated Roll Up Doors Included - sizes as noted in Key Features of your chosen building size. | 1 or 2 Insulated Roll Up Doors Included - sizes as noted in Key Features of your chosen building size. | You Select as many as are physically possible - sizes range from 8x8 through 18x16 |
Accessories | Assortment of Walk Doors, Windows, Insulation, Gutters and Downspouts, Wainscot, Premium Colored Roof Finish - as noted in Key Features of your chosen building size. | You Can Add On Walk Doors, Windows, Ridge Vents, Skylights, Insulation, Gutters and Downspouts, Wainscot, Premium Colored Roof Finish (if not already included in Base Model Key Features!) | Your choice of Roll Up Doors, Walk Doors, Windows, Ridge Vents, Skylights, Insulation, Gutters and Downspouts, Wainscot, Premium Colored Roof Finish, Roof Extensions. You let us know what you want! |
Choice of Profit | 3%-10% | 3%-10% | 5%-10% |
Fully Flashed Framed Openings | 1 or 2 Included for Roll Up Door - Locations as Shown in Sketches | 1 or 2 Included for Roll Up Door - Locations as Shown in Sketches | Framed Openings Quantity & Locations as desired. Portal Frame Bracing in lieu of X-Bracing if needed for your design. |
Walk Doors - Commercial Grade - White | 1 or 2 Insulated Walk Doors Included - As noted in Key Features of your chosen building size. Note: Frame Kit included in lieu of Walk Door for High Wind-Rated areas. | Add as many 3x7, 4x7 or 6x7 Insulated Walk Doors as you like. Note: Frame Kit offered in lieu of Walk Door for High Wind-Rated areas. Please buy door locally for savings. | Add as many 3x7, 4x7 or 6x7 Insulated or Non-Insulated Walk Doors as you like. Note: Frame Kit offered in lieu of Walk Door for High Wind-Rated areas. Please buy door locally for savings. |
Windows - Commercial Grade | 1 or 2 Insulated 3x3 Windows Included - As noted in Key Features of your chosen building size. | Add as many 2x7 Fixed, and 3x3, 4x3, 6x3 Horizontal Slide Insulated Windows... as you like. | Add as many 2x7 Fixed, and 3x3, 4x3, 6x3 Horizontal Slide Insulated or Non-Insulated Windows... as you like. |
Insulation | Fiberglass or Reflective Roof and Wall Insulation included - As noted in Key Features of your chosen building size. | Add in your choice of Fiberglass or Reflective Roof and Wall Insulation if desired. | Add in your choice of Fiberglass or Reflective Roof and Wall Insulation if desired. |
Gutters and Downspouts | Included in most Packages - As noted in Key Features of your chosen building size. Note: Northern Ice System included in 40+ lb snow loads. | Add on if not already included in Base Model. Note: Northern Ice System included in 40+ lb snow loads. | Add on if you desire. Note: Northern Ice System included in 40+ lb snow loads. |
Vents | Not Included | Add on Ridge Vents if desired. | Your choice of building vents and louvers. |
Skylights | Not Included | Add on Skylights in buildings over 30 width. | Add on Skylights in buildings over 30 width. |
Wainscot | Only in Executive Model | Included in Executive Model Add on available for all other Models. | Available as option for any building. |
Colors | Your choice of Wall, Trim and Roll Up Door Colors as shown. | Your choice of Wall, Trim and Roll Up Door Colors as shown. | Your choice of Wall, Trim and Roll Up Door Colors as shown. |
Colored Roof Finish | Included in some Packages - As noted in Key Features of chosen model. | Add on Premium Color Roof Finish if not already included in Base Model. | Your choice to add on Premium Color Roof Finish in your design. |
Buy Now! | Building Package: Option 1 | Custom Building Package: Option 2 | Custom Building: Option 3 |